Siwenoid Wiki

Supported subsystems

The fire, intrusion, I/O and video systems Siwenoid connects to, with links to their setup pages.

Siwenoid connects to each security system through a container: one container per panel, panel network or recording device. The container's handler type decides how Siwenoid talks to the device; its connection parameters say where the device is. Creating and switching a container on is described in Physical structure; the pages below add what is specific to each system: the device-side preparation, the connection parameters and how the datapoints get into Siwenoid.

Fire alarm systems

System Panels Connection Datapoints
Siemens Sinteso and Cerberus PRO (BACnet) Siemens Sinteso, Cerberus PRO BACnet/IP import
Siemens Cerberus CC11 and CC440 (Algorex) Siemens Cerberus CC11, CC440 serial line through a device server import
Esser fire alarm panels Esser panels with SEI module serial line through a converter import
Notifier AM6000 and AM6000N Notifier AM6000, AM6000N serial interface through a converter import
Aritech fire panels Aritech fire panels serial line through a converter import
INIM Previdia Max INIM Previdia Max Modbus TCP or RTU import
Minimax FMZ 5000 Minimax FMZ 5000 Modbus through a converter import
Schrack fire alarm system Schrack fire alarm system TCP import
Bosch FPA-5000 (FSI) Bosch FPA-5000 FSI, Ethernet import

Intrusion alarm systems

System Panels Connection Datapoints
Vanderbilt SPC Vanderbilt SPC EDP over UDP browse
Honeywell Galaxy Dimension Honeywell Galaxy Dimension SIA through a device server import
Satel Integra Satel INTEGRA INT-RS module through a converter browse
DSC PowerSeries NEO DSC PowerSeries NEO ITv2 over TCP browse
Texecom Premier and Premier Elite Texecom Premier, Premier Elite Simple Protocol through Com-IP import
Sintony SI410 Sintony SI410 serial line through a converter browse
Paradox EVO192 (PRT3) Paradox EVO192 PRT3 module through a converter browse
Paradox EVO, SP and MG (IP150) Paradox with IP150 IP150 browse

Intrusion panels also appear in the operator's intrusion view: see Intrusion view.

I/O and automation

System Device Connection Datapoints
Relaydroid Relaydroid I/O module HTTP by hand
Generic Modbus TCP PLCs and gateways Modbus TCP by hand

Video

System Devices Connection Datapoints
CCTV cameras (ONVIF, RTSP, Hikvision, Dahua) ONVIF, Hikvision and Dahua cameras and recorders, RTSP streams per type browse or by hand

How operators open cameras is described in Cameras (CCTV).

Ways to get datapoints in

Note

Each datapoint that represents a field device counts against the licence's datapoint limit. See Licensing.

Treatments and commands

The treatments of the handler type turn the device's events into statuses, and the commands of the handler type are the commands that can be sent. Each page says where they come from:

Important

At commissioning, before you switch the connection on, always check in Preferences › Datapoint types that the handler's types have treatments. If they have none and the handler has a treatment file, or you received an updated treatment file, import it: Importing a treatment file. Without treatments the device's events are not shown.

Serial-to-Ethernet converters

Where a serial-to-Ethernet converter makes a panel's serial line reachable over the network and the page prescribes no other device, the recommended converter is the ATC-2000. The ATC-1000 can freeze on a corporate network and is no longer used; some pages still show an ATC-1000 in their pictures. Siemens Cerberus CC11 and CC440 (Algorex) (Lantronix UDS1100 with a special firmware) and Notifier AM6000 and AM6000N (Moxa converter) prescribe their own devices.